Shut off the power supply to the air conditioner at the disconnect or breaker panel.
Outdoor hvac unit fan not running. Do not proceed if you re not sure you ve properly shut off the power. After some investigating you determine that your outside ac unit isn t running but the inside is. The first areas that should be checked and cleared can be completed easily and quickly. When you have a running compressor but your air conditioning unit is not producing cool air there are potentially a number of things that could be causing this problem.
And there are many things that can prevent the outdoor unit from starting some of which can be quite serious. Hi michael what could be a cause for an outdoor fan that starts with the ac unit but stops after the unit has run awhile maybe 20 25 minutes. It s located on the side of the building near the outdoor a c unit. To avoid the outside ac unit fan not spinning preventive maintenance is the best way to go.
Less frequent starts and stops of the fan can reduce the stress from startup and potentially help extend it s lifespan. Most companies do provide coverage for the capacitor for a limited period of time. Keeping the fan on creates a more even distribution of heating and cooling circulating the air if you have cold or hot spots in your house like a bedroom above a garage. This article discusses the diagnosis and repair of problems with the outdoor compressor condenser fan and fan motor including fans that wont run fans that run at slow speed and fans that won t stop running our page top photo of a compressor condenser fan unit shows that a stick had fallen into the fan blocking the blades and.
Also if the capacitor goes out on a fairly new unit check your warranty documentation. Remove the service panel on the a c unit. If you are in lawton ok or the surrounding area give your neighbors at pippin brothers home services a call. In this case the outdoor fan is not running due to a bad capacitor.
Here are a few of things you can do before calling an ac repair company. This is a very common problem whether it s an air conditioner or a heat pump. Pros to running fan on air conditioner continuously. A c or heat pump fan condenser unit diagnosis repair.
The motor is only about 6 months old because i replaced it due to this issue but the issue is still happening. Despite hearing the sound of the ac turning on your house is not cooling down as it used to. Typically this means one of two things. Outside ac unit not running.
Why your ac unit is not cooling. The fan is loose and not bound. Outdoor unit won t come on outdoor unit not running. Find the start capacitor for the fan.