Outdoor Ambient Temperature Sensor Error

The temperature sensors are mounted in a nema 4x enclosure with integral mounting tabs.
Outdoor ambient temperature sensor error. The computer uses this input along with other in car temperature. Outdoor ambient temperature sensor malfunction. Outdoor unit eeprom error. If not available use heat pump if outdoor.
Open or short circuit of indoor room or evaporator temperature sensor. Outdoor mid coil temperature sensor malfunction. Inverter module igbt over strong current protection. F1 ol 2 time tl on outdoor ambient temperature sensor t4 open circuit or short f2 ol 3 time tl on circuit.
The series o 4 outside air temperature sensors are great for monitoring ambient air temperatures in outdoor applications. Use elec heat if available for heating. Check sensor is installed correctly on control. Open circuit or short circuit of outdoor ambient temperature sensor t4.
Unit continues to operate. Outdoor coil temperature sensor is open or shorted sets temp to 20 f. The ntc sensor s resistance decreases as the outside air temperature increases. Indoor coil temperature sensor is open or shorted control board sets temp to 40 f.
The ambient atc or outside air temperature sensor is an ntc negative temperature coefficient sensor that informs the semiautomatic automatic temperature control system of outside air temperature. Compressor discharge high temperature protection. The sensor detects an abnormally low or high coil temperature. 43 communication failure with unit a 44 communication failure with unit b 45 communication failure with unit c 46 communication failure with unit d 47 unit a freeze protection 48 unit b freeze protection.
Condenser coil temperature sensor t3 open circuit or short circuit. Out unit low side value temperature sensor t2b open circuit or short. Outdoor discharge air temperature sensor. Cooling oil return cycle.
84 outdoor ambient temperature fault. Check unit placement if the outdoor unit is in a high temperature area wait until the ambient. Outdoor fan speed has been out of control. Open or short circuit of outdoor ambient or condenser temperature sensor.
Overvoltage or too low voltage protection. The sensor detects an abnormally low or high outdoor ambient temperature. Outdoor ambient temperature sensor open circuit or short circuit. 24 installation and maintenance service manual 14 18k.
Fan speed out of control. Open circuit or short circuit. System high pressure protection. System low pressure protection.