Osha Door Width Requirements
An exit route must meet minimum height and width requirements.
Osha door width requirements. This guide explains scoping and technical requirements for accessible entrances doors and gates in the ada standards. The occupational safety and health administration is the agency charged with enforcing workplace safety regulations. A door in a means of egress should allow for easy opening and closing. Stairway landings and platforms are at least the width of the stair and at least 30 inches 76 cm in depth as measured in the direction of travel.
Exit doors are required in businesses and osha requires that you as a business owner comply with certain regulations regarding those exit doors to ensure the safety of yourself and your employees in the event of a fire or other hazardous situation. Any projection from the ceiling must not reach a point less than six feet eight inches 2 0 m from the floor. 1910 25 b 5 when a door or a gate opens directly on a stairway a platform is provided and the swing of the door or gate does not reduce the platform s effective usable depth to. Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
Is an employer out of compliance with this exit route standard if the stairs are 22 inches. Where there is only one exit access leading to an exit or exit discharge the width of the exit and exit discharge must be at least equal to the width of the exit access. 1910 36 g 1 the ceiling of an exit route must be at least seven feet six inches 2 3 m high. Each exit route door must be free of decorations or signs that obscure the visibility of the exit route door.
This could mean either side hinged or pivot swinging doors. The osha exit route requirements 1910 36 g 2 state that the minimum width of any way of exit access shall in no case be less than 28 inches and the osha stair requirement 1910 24 d requires a minimum stair width of 22 inches. In existing structures the minimum width is 28 inches wide. 1910 37 b 4 if the direction of travel to the exit or exit discharge is not immediately apparent signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge.
29 cfr 1910 36 g the ceiling of an exit route must be at least seven feet six inches 2 3 m high. 1910 25 b 5 when a door or a gate opens directly on a stairway a platform is provided and the swing of the door or gate does not reduce the platform s effective usable depth to. The maximum door leaf width is 48 inches. Stairway landings and platforms are at least the width of the stair and at least 30 inches 76 cm in depth as measured in the direction of travel.