Operating Room Ceiling Requirements
Ceiling heights should achieve the minimum recommended height and comply with equipment manufacturers installation requirements.
Operating room ceiling requirements. Modular room and ceiling elements from getinge s product range maquet variop allow hospitals to design every aspect of the operating room in line with their requirements. Cleanroom technology unlike traditional laminar airflow systems the cleansuite ceiling system helps mitigate the risk of airborne particles and prevents gaps within the room air. Operating spaces designed for specialized procedures generally require more staff and are recommended to be at least 600 square feet. Porous acoustical ceiling panels should be replaced with nonporous ceiling panels.
For the purposes of the guidelines however an invasive procedure is defined as a procedure that penetrates the protective surfaces of a patient s body e g skin or. Smooth scrubbable ceiling panels meet fgi guidelines for areas where healthcare workers are divesting ppe. A 400 square foot operating room requires a sterile field of 3 feet each side and foot of operating table a circulation pathway of 3 feet both sides and 2 feet at foot of sterile field and movable equipment zone of 2 feet 6 inches clear on both sides and 2 feet at foot of the circulation pathway. Suspension systems clean room suspension systems should be considered for the best performance in any healthcare space.
A minimum ceiling height of 3000mm is required in operating rooms interventional imaging rooms and birthing rooms. Ceiling mounted equipment must be able to achieve the required clearance height of 2150mm. Fgi provides baseline requirements for design of hybrid ors in the 2018 fgi guidelines for design and construction of hospitals 1 section 2 2 3 3 4 1 hybrid operating room. The cleansuite ceiling system offers.
Anesthesia work zone requires the same 6 feet. In its 2014 operating room requirements guidelines the facility guidelines institute recommends that the minimum inpatient operating room size be no less than 400 square feet. Fortunately the airframe team is here to help. The individual elements are sealed to the substructure for effective pressure regulation.
With the increased complexity of today s surgical and imaging requirements coordination of the operating room ceiling space can prove challenging. Application states a hybrid or shall be designed to comply with the requirements for operating rooms and the requirements for imaging services that 1facility guidelines. Validated particle counts at 100 particles per cubic foot it is the only solution to achieve the iso class 5 cleanroom specification surpassing the american society of.