Ontario Electrical Code Kitchen Counter Receptacles
A 20 amp receptacle is designed to accept the special plug on heavier use appliances and if such an appliance plugs into a 15 amp circuit there is a danger of drawing too much power and.
Ontario electrical code kitchen counter receptacles. In addition at least one receptacle outlet should be located within 600 mm 2 ft of the outer end of. Methods of wiring a home may be used but must meet the canadian electrical code. Kitchen islands and new receptacle requirements in the 2020 nec. However this requirement predates the requirement for counter receptacles and circuits.
Most of it however originates from people who work in the field. It is fed by a 2 pole 15a circuit breaker and uses 14 2 cable. Small kitchen appliance cords such as coffee pots toasters and mixers rarely have a power cord that is more than 24 inches long. Kitchen wall not counter receptacles 2015 code separate branch circuit required 2018 code separate branch circuit not required wall receptacles provided in a kitchen are required to be supplied by a separate circuit.
There is no danger to installing 15 amp outlet receptacles on a 20 amp circuit in fact this is the standard practice but under no circumstances should a 20 amp receptacle be installed on a 15 amp circuit. The following guide includes the canadian electrical code in effect as of february 1 2019. Since it is not desirable to use an extension cord on these devices most electrical codes require a higher number of electrical outlets above a kitchen counter than anywhere else in the home. A receptacle outlet is then required for every additional 1 7 m 2 18 ft 2 of countertop or work surface.
These kitchen designs mean that electrical contractors need to find new ways to satisfy rule 26 712 d iii which outlines the number of receptacles needed and provides a method to determine location. This is what is known as a split receptacle kitchen circuit. There can be no part of the countertop farther than 24 inches from an outlet which means that the maximum spacing between countertop receptacles is 48 inches. This guide is meant to assist users and every effort has been made to ensure it reflects the current code however where discrepancies between this and.
When planning out kitchen receptacle placement it is important to remember that the rule talks about counter work surfaces not wall spaces. Understanding the kitchen split receptacle circuit. Electricians contractors and other industry professionals. The nec doesn t specify the number of receptacle outlets you must have in the kitchen but it does have a specific requirement for outlets serving counter spaces more than 12 inches long.